Carel heaterSteam Specifications Page 32

  • Download
  • Add to my manuals
  • Print
  • Page
    / 52
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 31
CAREL heaterSteam
32
DISPLAYED CODE
H and T
control
graphic
terminal
CAUSE SOLUTION ACTION RESET ALARM
RELAY
EA
E215
excessive foam - Clean the cylinder and check that the
steam supply pipe is not crimped along its
path and that there are no obstructions or
pockets of condensed water.
Signal only Automatic active
EU Full cylinder, no demand - Leaking fill valve
- Dirty high level / foam sensor
Signal only Automatic Active
Ed Faulty drain - Check/clean drain valve/pump Signal only Automatic Active
E ¯
E221
High humidity
- Check the operation of the sensor and
the limit set by parameter P2.
Signal only Automatic
E _
E222
Low humidity
- Check the operation of the sensor and
the limit set by parameter P3.
active
E =
E224
High humidity in supply air - Check the operation of the sensor no. 2 active
E0
E201
CAREL parameter error
- Contact Carel’s service department. De-
energized
humidifier
CAREL
Re-
programming
active
E1
E212
User parameter error - Re-enter the set parameters or recall the
default parameters
- Check for bad wiring connections
Parameter
Re-
programming
E2 E230 Hour counter error
- Reset hour counter
See pg. 30, item 4.3
Deactivatio
n of the
memory of
the counter
Hour-
counter
manual
reset
idle
E3
E220
Control sensor not
connected
- Check the connection of the sensor or
the setting of parameter A0 for
configuration in ON - OFF
De-
energised
humidifier
E4
E223
High limit sensor not
connected
- Check the connection of the sensor or
the setting of parameter A0.
Automatic active
E5
E225
Pre -heating NTC probe not
connected
- Check the effective pre-heating
functioning and b1, b2 and b3 parameter
set.
- Check the 5 pole terminal connections
on the cylinder cover.
Pre-heating
de-
energized
CL
E232
Maintenance warning
- Stop the unit and clean the steam
cylinder, filter and water level switches.
signal only Hour-
counter
reset
idle
Page view 31
1 2 ... 27 28 29 30 31 32 33 34 35 36 37 ... 51 52