Distributor pipes should be mounted per the diagrams shown below, with a minimum of 6” from the center of
the distributor pipe to the top of the duct and 3” minimum to the bottom.
To install the distributor pipes:
1. Cut a key shaped hole in the side of the duct to match the steam pipe and condensate return.
2. Apply silicone sealant to the mounting plate and insert the pipe through the hole and secure it with 4 sheet
metal screws.
3. Connect the steam and condensate hoses using the hose clamps supplied.
(Note: end support bracked supplied only with 36” and longer distributors.)
IMPORTANT: Allow 2 feet of straight duct dow nstream of the distributor pipes when the air temperature
w ill be >55
o
F. Allow 3 feet of straight duct if the air temperature will be <50
o
F. Alw ays allow 2 feet
upstream. Turbulent air flow may require longer lengths.