humiSteam Lite commercial electrode steam humidifiers Installation Operation User Manual Read and save these instructions.
CAREL humiSteam Lite 10 1.3 Plumbing 1.3.1 Water supply The HumiSteam must be supplied with water (not softened) having the following characteristic
Installation, Operating & Maintenance Manual 11 1.3.2 Water drain The HumiSteam also requires connection to a drain. The drain water characte
CAREL humiSteam Lite 12 Physical location of the supply and drain connections are located as shown below. NOTE: Carel can provide a drain temper
Installation, Operating & Maintenance Manual 13 1.4 Steam distribution 1.4.1 Duct injection If you are using stainless steel duct steam distri
CAREL humiSteam Lite 14 1.4.2 Steam Hoses NINETY PERCENT (90%) OF ALL OPERATION PROBLEMS ARE CREATED BY IMPROPER STEAM PIPING FROM THE HUMIDIFIER
Installation, Operating & Maintenance Manual 15 1.4.3 Room distribution blower units Refer to the manual supplied with the Room Distribution
CAREL humiSteam Lite 16 1.5 Power wiring Check that the power supply voltage to be connected matches the value indicated on the rating plate inside
Installation, Operating & Maintenance Manual 17 1.6 Control wiring The HumiSteam Lite control system allows one humidistat to be connected, a
CAREL humiSteam Lite 18 For On/Off Operation (diagram at right): Connect any simple humidistat, high-limits, air flow switch, and remote conta
Installation, Operating & Maintenance Manual 19 1.6.1 REHUMST Wall and Duct Humidistat The REHUMST is designed to operate as a wall mount or
CAREL humiSteam Lite 2
CAREL humiSteam Lite 20 1.6.2 PC-301 Air Proving Switch Mounting the PC-301 air flow switch: Mount the airflow switch in the supply or return duct
Installation, Operating & Maintenance Manual 21 2 Start-Up IMPORTANT WARNINGS: 1. Before starting, check that the humidifier is in perfect c
CAREL humiSteam Lite 22 2.2 The HumiControl Controller The HumiSteam Lite uses an LED version of the HumiControl, which communicates all information
Installation, Operating & Maintenance Manual 23 3.3 Alarms In the event of an alarm, the alarm LED will flash, the alarm relay will close, and
CAREL humiSteam Lite 24 3.4 Trouble-Shooting problem causes solutions the humidifier does not turn on 1. no electrical power 2. on/off switch of
Installation, Operating & Maintenance Manual 25 problem causes solutions Water in the cylinder turns black 1. minerals in the cylinder have
CAREL humiSteam Lite 26 4 Maintenance 4.1 Periodic checks • After one hour of operation: For both disposable and cleanable cylinders, check that th
Installation, Operating & Maintenance Manual 27 Connection of single or three phase UE 001 to 015 models Maintenance of the other plu
CAREL humiSteam Lite 28 4.3 Replacement Parts 4.3.1 Single Phase Humidifiers Standard spare parts Model UE003 UE005 Water parts fill cup + co
Installation, Operating & Maintenance Manual 29 5 Wiring Diagrams UE003, UE005 Single Phase
Installation, Operating & Maintenance Manual 3 IMPORTANT BEFORE INSTALLING OR HANDLING THE HUMIDIFIER PLEASE CAREFULLY READ AND FOLLOW THE
CAREL humiSteam Lite 30 6 Technical Specifications UNIT MODEL NUMBER CAPACITY AMPERAGE WATTAGE VAC Phase Factor UE003 UE005 Lbs/hr 6.6 11 2
Installation, Operating & Maintenance Manual 31
CAREL humiSteam Lite 32 Limited Warranty All products manufactured by CAREL USA are warranted to the original purchas
CAREL humiSteam Lite 4
Installation, Operating & Maintenance Manual 5 Table of Contents Models And Description Of The Components ...
CAREL humiSteam Lite 6 Models and Description of the Components Model Selection UE 003 P D 000 U 1 0 UE = Electrode Capacity (KG) P Control Powe
Installation, Operating & Maintenance Manual 7 How the HumiSteam Works HumiSteam is an electrode humidifier. It produces steam for humidifica
CAREL humiSteam Lite 8 1 Installation 1.1 Positioning The HumiSteam has been designed for wall mounting (although it can be placed on a stand) and,
Installation, Operating & Maintenance Manual 9 1.2 Mounting 1.2.1 Removing the front cover The front cover is secured by a capture screw locat
Comments to this Manuals